ACTA MEDICA
ACTA MEDICA
Acta Medica (Hradec Králové) je víceoborový vědecký recenzovaný časopis vycházející v angličtině. Acta Medica publikují review, původní články, stručná sdělení, případové studie a oznámení. Časopis byl založen v roce 1958 pod názvem Sborník vědeckých prací Lékařské fakulty Univerzity Karlovy v Hradci Králové. Je indexován v databázích Chemical Abstracts, CNKI, DOAJ, EBSCO, Hinari, Index Medicus, MEDLINE, Scopus a Ulrichsweb.

ACTA MEDICA, Vol 68 No 1 (2025), 14–20

Clinical Evaluation of Oxidized Cellulose Powder and Endoscopic Applicator in Multicenter Trial

Petr Habal, Veronika Sívková, Zdeněk Šorm, Milan Chobola, Jiří Feix, Igor Slaninka, Jiřina Habalová, Tomáš Hosszú, Jaroslav Pacovský

DOI: https://doi.org/10.14712/18059694.2025.13
zveřejněno: 16. 06. 2025

Abstract

Purpose: Oxidized cellulose-based haemostatic agents are widely used for managing bleeding in various surgical procedures. This study evaluates the efficacy and safety of oxidized cellulose powder and an endoscopic applicator across a broad spectrum of surgical settings. Methods: This was a prospective, multicentre study involving 99 evaluable patients undergoing surgeries with varying bleeding severities and surgical approaches (open, laparoscopic, or thoracoscopic). The primary endpoint was achieving haemostasis within 3 minutes and avoiding revision surgery within 12 hours. The time to haemostasis (TTH) and complications were recorded, and statistical comparisons were made using a paired and unpaired t-test, with a significance threshold of P < 0.05. Data from this study were compared to historical results from fibrillar haemostats. Results: Haemostasis was achieved within 3 minutes in 61.6% (95% CI [52.0, 71.2]) of patients and within 5 minutes in 99.0% (95% CI [97.0, 100.0]) of patients. The overall mean TTH was 153.8 seconds (95% CI: 141.5–166.1), with shorter TTH observed in minimally invasive procedures using the endoscopic applicator. Subgroup analysis revealed higher success rates for patients with mild bleeding (78%) compared to moderate bleeding (50%). Conclusion: Oxidized cellulose powder demonstrates reliable haemostatic performance across diverse surgical applications. The endoscopic applicator enhances precision and applicability, particularly in minimally invasive settings, making it a valuable tool in modern surgical practice.

klíčová slova: oxidized cellulose; haemostasis; endoscopic applicator; haemostatic powder; Traumastem

Creative Commons License
Clinical Evaluation of Oxidized Cellulose Powder and Endoscopic Applicator in Multicenter Trial is licensed under a Creative Commons Attribution 4.0 International License.

210 x 297 mm
vychází: 4 x ročně
cena tištěného čísla: 150 Kč
ISSN: 1211-4286
E-ISSN: 1805-9694

Ke stažení