ACTA MEDICA
ACTA MEDICA
Acta Medica (Hradec Králové) is an English language multidisciplinary medical journal. Acta Medica publishes reviews, original articles, brief communications, case reports, announcements, and notices. The journal was founded in 1958 under the title “A Collection of Scientific Works of the Charles University’s Faculty of Medicine in Hradec Králové”. The journal is indexed in Chemical Abstracts, CNKI, DOAJ, EBSCO, Hinari, Index Medicus, MEDLINE, Scopus, and Ulrichsweb.

ACTA MEDICA, Vol 68 No 1 (2025), 14–20

Clinical Evaluation of Oxidized Cellulose Powder and Endoscopic Applicator in Multicenter Trial

Petr Habal, Veronika Sívková, Zdeněk Šorm, Milan Chobola, Jiří Feix, Igor Slaninka, Jiřina Habalová, Tomáš Hosszú, Jaroslav Pacovský

DOI: https://doi.org/10.14712/18059694.2025.13
published online: 16. 06. 2025

abstract

Purpose: Oxidized cellulose-based haemostatic agents are widely used for managing bleeding in various surgical procedures. This study evaluates the efficacy and safety of oxidized cellulose powder and an endoscopic applicator across a broad spectrum of surgical settings. Methods: This was a prospective, multicentre study involving 99 evaluable patients undergoing surgeries with varying bleeding severities and surgical approaches (open, laparoscopic, or thoracoscopic). The primary endpoint was achieving haemostasis within 3 minutes and avoiding revision surgery within 12 hours. The time to haemostasis (TTH) and complications were recorded, and statistical comparisons were made using a paired and unpaired t-test, with a significance threshold of P < 0.05. Data from this study were compared to historical results from fibrillar haemostats. Results: Haemostasis was achieved within 3 minutes in 61.6% (95% CI [52.0, 71.2]) of patients and within 5 minutes in 99.0% (95% CI [97.0, 100.0]) of patients. The overall mean TTH was 153.8 seconds (95% CI: 141.5–166.1), with shorter TTH observed in minimally invasive procedures using the endoscopic applicator. Subgroup analysis revealed higher success rates for patients with mild bleeding (78%) compared to moderate bleeding (50%). Conclusion: Oxidized cellulose powder demonstrates reliable haemostatic performance across diverse surgical applications. The endoscopic applicator enhances precision and applicability, particularly in minimally invasive settings, making it a valuable tool in modern surgical practice.

keywords: oxidized cellulose; haemostasis; endoscopic applicator; haemostatic powder; Traumastem

Creative Commons License
Clinical Evaluation of Oxidized Cellulose Powder and Endoscopic Applicator in Multicenter Trial is licensed under a Creative Commons Attribution 4.0 International License.

210 x 297 mm
periodicity: 4 x per year
print price: 150 czk
ISSN: 1211-4286
E-ISSN: 1805-9694

Download